Two GE Rad Rooms – Optima XR640 & Definium 8000

☆ Both machines are scheduled to be removed by 12/6/21.  We’re checking on flexibility.

☆ Newish tubes and collimators.

☆ One detector for both machines.

☆ XR640 is used for imaging and Definium 8000 is used for stitching.

2011 and 2007 GE Optima XR640 & Definium 8000 Rad Room

ID
75479
Type
Rad Room
Manufacturer
GE
Model
Optima XR640 & Definium 8000
Year of MFG
2011 and 2007
Condition
Good

Details

Condition Notes
The machines are under GE service.
Date of Availability
12/06/2021
Geographical Location
Boston
Are the software disk(s) present?
Yes
Is the equipment under service?
Yes
Is the device digital or analog?
Digital
Number of Detectors
1
Detector Type
2393824
Current Tube Model
MX100 09PS (2)
Tube Manufacture Date
2019 (2)
Collimator
AL01C II | 10092624 (2)
Are the manuals present?
Yes
Egress Description
Easy. Approximately 100'. Take a right out of the rooms, travel 20'. Go left, travel 30'. Take a right, travel 50'. Take a right, travel 15'. Open the door to the parking lot. Box truck with lift gate required. Flat ground, plenty of parking. Removal after 5pm, but patient-conscious work can start earlier. Truck can be parked immediately outside the door after 5. Truly an ideal egress.

Images

Equipment Listing Images Gallery (18 images)
Click image to zoom in
Previous Review Next Review
Software Options Screens Gallery (5 images)
Click image to zoom in
Previous Review Next Review

Documents

Notes

Room 1 Details:

Original Install Date:

            09-11-2011

 

Table:

            P/N: 5176260

            MFG: 2011

 

Bucky:

           Missed it.  We can collect the information if necessary.

 

Generator:

           P/N: Jedi 80RD 1T | 2374870

           MFG: 2011

 

P/N: 5517079

           MFG: 2013

 

            P/N: 5305071

            MFG: 2011

 

Collimator:

           P/N: AL01C II | 10092624

           MFG: 2021

 

Tube:

           P/N: MX100 09PS |2336058 |46-155400G46

           MFG: 2019

           Both tubes are 2019

 

Detector:

           P/N 2393824

 

See Images for Software and Firmware Versions

Room 2 Details:

Original Install Date:

           12-31-2007

 

Table:

           No Table / Rolling table.  This room is mostly used for stitching.

 

Bucky:

           P/N: 5141608-2

           MFG: 2007

 

Generator:

           P/N: Jedi 80RD 1T | 2374870

           MFG: 2011

 

P/N: 5517088

           MFG: 2013

 

           P/N: Thunder System Cabinet | 5128145

           MFG: 2007

 

Collimator:

           P/N: AL01C II | 10092624

           MFG: 2016

 

Tube:

           P/N: MX100 09PS |2336058 |46-155400G46

           MFG: 2019     

           Both tubes are 2019

 

Detector:

           N/A – One detector is used between both rooms.

 

See Images for Software and Firmware Versions